The EMA 52 microelement analyzer provides an accurate and reliable solution for the determination of carbon, hydrogen, nitrogen, sulfur and oxygen. The device is also suitable for receiving and analyzing solid and liquid samples.
It can accommodate up to 117 samples, which requires a total of 4 sample change discs. Thanks to the EMASoft PC software included with the device, it does not require the continuous presence of the analyst. It can even work independently at night. An analysis of approx. It takes 3-4 minutes, so you can measure the 117 samples within 8 hours (e.g. during night work).
Gas chromatography technology ensures complete separation of all elements and real-time peak data. By connecting to the Velp ERMES cloud-based storage, the operation of the device can be monitored or controlled remotely from a phone, computer or tablet.
The device works according to the following international standards: AOAC, AACC, ASBC, ISO, DIN, IFFO, OIV, ASTM, EPA.
More detailsSpecifications: | EMA 502 microelement analyzer |
---|---|
Sensor: | TCD sensor with automatic calibration |
Maximum sample weight: | up to 100 mg (depending on carbon content) |
Automatic sample changer capacity: | 4 discs with 30 positions each (supplied with 1 disc) |
Accuracy: | ≤ 0.2 % |
Connectivity: | to the cloud with a Wi-Fi connection or LAN |
Dimensions (W x H x D): | 500 x 510 x 410 mm (height with automatic sample changer: 680 mm) |
Weight: | 45 kg |
Combustion / pyrolysis temperature: CHNS: 1030°C O: 1060°
EMA 502 can use two types of carrier gas. Since Helium is very expensive, so where the use of Argon is permissible, it will be economical to use this carrier gas
Measuring ranges: | EMA 502 | |
---|---|---|
He carrier gas | AR carrier gas | |
Analytical range, C: | 0.001 - 20 mg | 0.01 - 20 mg |
Analytical range, H: | 0.001 - 5 mg | 0.01 - 5 mg |
Analytical range, N: | 0.001 - 20 mg | 0.01 - 20 mg |
Analytical range, S: | 0.01 - 6 mg | - |
Analytical range, O: | 0.005 - 6 mg | - |
Sales package includes: device, automatic sample changer with 1 sample changer disc, consumable kit for 1,000 measurements, GC column - CHNS, EMASoft PC software, 1 year access to the VELP Ermes Cloud platform, USB and RS-232 cable. The computer is provided by the user!
For oxygen analysis, in addition to the device, you must order the following accessories:
The protein/nitrogen determination, which does not require wet chemical sample preparation, works based on the Dumas method