Request a price
MEMMERT's test chambers provide a perfect simulation space for material and aging tests and functional tests. Both climate chambers can reach +180°C from the harsh arctic cold in just 20 minutes (The process takes 80 minutes in reverse). A total of 40 arbitrary temperature program steps can be set in the controller.
The CTC 256 climatic test chamber is also equipped with a humidity controller, with which the interior of the device can be hydrated or dehydrated between 10 and 98% relative humidity in the temperature range of +10°C and +95°C. The computer is connected via a USB connector, however, optionally, the test chambers can also be connected to the local computer network.
Specifications: | CTC 256 | TTC 256 |
---|---|---|
Volume: | 256 liters | 256 liters |
Consumption: | 7000 Watt | 7000 Watt |
Temperature range without humidity control: | -42°C - +190°C | -42°C - +190°C |
Temperature range with humidity control: | +10°C - +95°C | - |
Heating speed: | 10 K / minute | 10 K / minute |
Cooling speed: | 6 K / minute | 6 K / minute |
Humidity: | 10 - 98% | - |
Controller accuracy: | ±0.1°C | ±0.1°C |
Temperature inhomogenity: | ±0.3°C | ±0.4°C |
Internal dimensions: | 640 x 670 x 597 mm | 640 x 670 x 597 mm |
External dimensions: | 898 x 1730 x 1100 mm | 898 x 1730 x 1100 mm |
Weight (net, gross): | 260 / 420 kg | 260 / 420 kg |
Voltage: | 400 V, 3 phase | 400 V, 3 phase |
PERFECT (P) programmable controller with card writer/reader: programming can be done directly on the device (40-step program), with the memory card (40-step program), and with the computer, an almost infinite number of temperature steps can be set. The degree of air mixing and ventilation can be programmed for some stairs. Connected to a computer with the CELSIUS 2005 program, the continuously measured data can be displayed in a table or graphically. Data can be collected for up to 6 days (memory 1,024 kB). With the optional card writer/reader unit - which is connected to the PC - the data will be portable, and a new program can also be written on the computer. Connectors: RS 232 and printer output (optional USB and LAN). Triple protection against overheating: electronic (TWW or TWB) and mechanical (TB), as well as an adjustable tolerance limiter. In case of overheating, the device sounds an alarm. The factory CELSIUS 2005 evaluation program and a memory card are standard accessories.
HCP humidity chamber, plant breeding chamber. Suitable for heating and humidification, with a volume between 56 and 241 liters. HPPeco constant climate chamber with cooling and humidification, as well as lighting option. With a volume between 110 and 2140
More informationsMemmert's dedicated devices for stability testing of pharmaceutical products with optional UV illumination or carbon dioxide control, in volumes of 110, 260 and 750 liters.
More informationsStainless steel shelves can be ordered separately for Memmert drying ovens, hot air sterilizers, incubators, climate and humidity chambers.
More informations