Laboreszköz katalógus
Marketplace 0Cart
Transport media, Amies
Transport media, Amies
Transport media, liquid Amies
Transport media, liquid Amies
Transport media, Stuart
Transport media, Stuart
Transport media, Cary Blair
Transport media, Cary Blair
Transport media, virus
Transport media, virus
Transport media, Chlamydia
Transport media, Chlamydia
Transport media, Amies
Transport media, liquid Amies
Transport media, Stuart
Transport media, Cary Blair
Transport media, virus
Transport media, Chlamydia

Transport media, sterile, labeled, with sampling swab, also for Covid-19!

Deltalab

Request a price


Storage tube size: (d x h) 13 x 165 mm.

Stuart media: thioglycate content inhibits the growth of germs for 24 hours. Recommended use: Neisseria gonorrhoeae, Heamophilus influenzae, diphtheriae, Trichomonas vaginalis, Streptococcus sp., Salmonella sp., Shigellas sp., etc.

Cary Blair media: modified Stuart medium without methylene blue, with inorganic phosphate (pH 8.4), with glycerophosphate. Recommended use: Neisseria sp., Heamophilus sp., Streptococcus sp. It can also be used to transport anaerobic bacteria.

Amies media: modified Stuart medium with methylene blue, glycerophosphate and inorganic with phosphatase content. Calcium and magnesium maintain the bacterial cell wall permeability. It inhibits the growth of germs for 48 hours. Recommended use: Neisseria sp., Trichomonas vaginalis, Corynebacteria, Heamophilus sp., Streptococcus sp, Enterobacteraceae.

Liquid Amies media: traditional Amies medium, inhibits the growth of germs for 48 hours. Recommended use: Neisseria sp., Trichomonas sp., Heamophilus sp., Salmonella sp.

Media for viruses: preserves the cell count of the sample for 72 hours. Its additives inhibit the growth of bacteria and fungi

Chlamydia media: liquid, stabilizes for 72 hours after sampling pattern.

Type 22.300298 is suitable for the COVID-19 virus. Only while stocks last!

picture
code
Order unit
Shelf life
Composition
Wand dimension d x h
Media type
net price
amount
in stock
22.300281
100 pc
30 month
aluminium stem / viscose head
150 x 0,9 mm
Amies
Request a price Sale product
box

Swabs are Sterilised by radiation. Swab: CE MDD Class IIa. Tube: CE IVD. AMIES media is a modification of Cary Blair media, which is at the same time a modification of Stuart media. Basically the glycerophosphate is replaced by an inorganic phosphate, and the methylene blue by pharmacological charcoal. Calcium and magnesium are also added, thus maintaining the permeability of the bacterial cell. This media assures the viability of organisms such as: Neisseria sp., Haemophilus sp., Corynebacterium sp., Trichomonas vaginalis, Streptococcus pyogenes, Streptococcus pneumoniae, Shigella flexneri, Salmonella typhi, Brucella abortus, Enterobacterias, etc. Some microorganisms can resist on the media for up to 3 days, although the recovery of microorganisms is better if cultured in the first 24 hours. Dimensions of tube: 165x13 mm. Al shaft: 150x0,9 mm. Tip D=5 mm. Expiry date: 30 months after Sterilisation date.

Swabs are Sterilised by radiation. Swab: CE MDD Class IIa. Tube: CE IVD. AMIES media is a modification of Cary Blair media, which is at the same time a modification of Stuart media. Basically the glycerophosphate is replaced by an inorganic phosphate, and the methylene blue by pharmacological charcoal. Calcium and magnesium are also added, thus maintaining the permeability of the bacterial cell. This media assures the viability of organisms such as: Neisseria sp., Haemophilus sp., Corynebacterium sp., Trichomonas vaginalis, Streptococcus pyogenes, Streptococcus pneumoniae, Shigella flexneri, Salmonella typhi, Brucella abortus, Enterobacterias, etc. Some microorganisms can resist on the media for up to 3 days, although the recovery of microorganisms is better if cultured in the first 24 hours. Dimensions of tube: 165x13 mm. Al shaft: 150x0,9 mm. Tip D=5 mm. Expiry date: 30 months after Sterilisation date.

22.300287
100 pc
30 month
polystyrene stem / viscose head
150 x 2,5 mm
Amies
Request a price Sale product
unit

Swabs are Sterilised by radiation. Swab: CE MDD Class IIa. Tube: CE IVD. AMIES media is a modification of Cary Blair media, which is at the same time a modification of Stuart media. Basically the glycerophosphate is replaced by an inorganic phosphate, and the methylene blue by pharmacological charcoal. Calcium and magnesium are also added, thus maintaining the permeability of the bacterial cell. This media assures the viability of organisms such as: Neisseria sp., Haemophilus sp., Corynebacterium sp., Trichomonas vaginalis, Streptococcus pyogenes, Streptococcus pneumoniae, Shigella flexneri, Salmonella typhi, Brucella abortus, Enterobacterias, etc. Some microorganisms can resist on the media for up to 3 days, although the recovery of microorganisms is better if cultured in the first 24 hours. Dimensions of tube: 165x13 mm. PS shaft: 150x2.5 mm. Tip D=5 mm. Expiry date: 30 months after Sterilisation date.

Swabs are Sterilised by radiation. Swab: CE MDD Class IIa. Tube: CE IVD. AMIES media is a modification of Cary Blair media, which is at the same time a modification of Stuart media. Basically the glycerophosphate is replaced by an inorganic phosphate, and the methylene blue by pharmacological charcoal. Calcium and magnesium are also added, thus maintaining the permeability of the bacterial cell. This media assures the viability of organisms such as: Neisseria sp., Haemophilus sp., Corynebacterium sp., Trichomonas vaginalis, Streptococcus pyogenes, Streptococcus pneumoniae, Shigella flexneri, Salmonella typhi, Brucella abortus, Enterobacterias, etc. Some microorganisms can resist on the media for up to 3 days, although the recovery of microorganisms is better if cultured in the first 24 hours. Dimensions of tube: 165x13 mm. PS shaft: 150x2.5 mm. Tip D=5 mm. Expiry date: 30 months after Sterilisation date.

22.3002811
100 pc
30 month
aluminium stem / viscose head
150 x 0,9 mm
Amies + coal
Request a price Sale product
box

Swabs are Sterilised by radiation. Swab: CE MDD Class IIa. Tube: CE IVD. AMIES media is a modification of Cary Blair media, which is at the same time a modification of Stuart media. Basically the glycerophosphate is replaced by an inorganic phosphate, and the methylene blue by pharmacological charcoal. Calcium and magnesium are also added, thus maintaining the permeability of the bacterial cell. This media assures the viability of organisms such as: Neisseria sp., Haemophilus sp., Corynebacterium sp., Trichomonas vaginalis, Streptococcus pyogenes, Streptococcus pneumoniae, Shigella flexneri, Salmonella typhi, Brucella abortus, Enterobacterias, etc. Some microorganisms can resist on the media for up to 3 days, although the recovery of microorganisms is better if cultured in the first 24 hours. Dimensions of tube: 165x13 mm. Al shaft: 150x0.9 mm. Tip D=5 mm. Expiry date: 30 months after Sterilisation date.

Swabs are Sterilised by radiation. Swab: CE MDD Class IIa. Tube: CE IVD. AMIES media is a modification of Cary Blair media, which is at the same time a modification of Stuart media. Basically the glycerophosphate is replaced by an inorganic phosphate, and the methylene blue by pharmacological charcoal. Calcium and magnesium are also added, thus maintaining the permeability of the bacterial cell. This media assures the viability of organisms such as: Neisseria sp., Haemophilus sp., Corynebacterium sp., Trichomonas vaginalis, Streptococcus pyogenes, Streptococcus pneumoniae, Shigella flexneri, Salmonella typhi, Brucella abortus, Enterobacterias, etc. Some microorganisms can resist on the media for up to 3 days, although the recovery of microorganisms is better if cultured in the first 24 hours. Dimensions of tube: 165x13 mm. Al shaft: 150x0.9 mm. Tip D=5 mm. Expiry date: 30 months after Sterilisation date.

22.300285
100 pc
30 month
polystyrene stem / viscose head
150 x 2,5 mm
Amies + coal
Request a price Sale product
box

Swabs are Sterilised by radiation. Swab: CE MDD Class IIa. Tube: CE IVD. AMIES media is a modification of Cary Blair media, which is at the same time a modification of Stuart media. Basically the glycerophosphate is replaced by an inorganic phosphate, and the methylene blue by pharmacological charcoal. Calcium and magnesium are also added, thus maintaining the permeability of the bacterial cell. This media assures the viability of organisms such as: Neisseria sp., Haemophilus sp., Corynebacterium sp., Trichomonas vaginalis, Streptococcus pyogenes, Streptococcus pneumoniae, Shigella flexneri, Salmonella typhi, Brucella abortus, Enterobacterias, etc. Some microorganisms can resist on the media for up to 3 days, although the recovery of microorganisms is better if cultured in the first 24 hours. Dimensions of tube: 165x13 mm. PS shaft: 150x2.5 mm. Tip D=5 mm. Expiry date: 30 months after Sterilisation date.

Swabs are Sterilised by radiation. Swab: CE MDD Class IIa. Tube: CE IVD. AMIES media is a modification of Cary Blair media, which is at the same time a modification of Stuart media. Basically the glycerophosphate is replaced by an inorganic phosphate, and the methylene blue by pharmacological charcoal. Calcium and magnesium are also added, thus maintaining the permeability of the bacterial cell. This media assures the viability of organisms such as: Neisseria sp., Haemophilus sp., Corynebacterium sp., Trichomonas vaginalis, Streptococcus pyogenes, Streptococcus pneumoniae, Shigella flexneri, Salmonella typhi, Brucella abortus, Enterobacterias, etc. Some microorganisms can resist on the media for up to 3 days, although the recovery of microorganisms is better if cultured in the first 24 hours. Dimensions of tube: 165x13 mm. PS shaft: 150x2.5 mm. Tip D=5 mm. Expiry date: 30 months after Sterilisation date.

22.300284
100 pc
30 month
polystyrene stem / viscose head
150 x 2,5 mm
liquid Amies
Request a price Sale product
box

Swabs are Sterilised by radiation. Swab: CE MDD Class IIa. Tube: CE IVD. This is a variation of the traditional Amies media swab where the media is presented on liquid form without agar. Suitable for conservation of pathogens such as: Haemophilus sp., Corynebacterium sp., Trichomonas vaginalis, Streptococcus pyogenes, Streptococcus pneumoniae, Shigella flexneri, Salmonella typhi, Brucella abortus, Staphylococcus epidermidis, Escherichia coli, etc. Media is supplied in its liquid form, in a sponge, suitable for direct extensions on slides. Dimensions of tube: 165x13 mm. PS shaft: 150x2.5 mm. Tip D=5 mm. Expiry date: 30 months after Sterilisation date.

Swabs are Sterilised by radiation. Swab: CE MDD Class IIa. Tube: CE IVD. This is a variation of the traditional Amies media swab where the media is presented on liquid form without agar. Suitable for conservation of pathogens such as: Haemophilus sp., Corynebacterium sp., Trichomonas vaginalis, Streptococcus pyogenes, Streptococcus pneumoniae, Shigella flexneri, Salmonella typhi, Brucella abortus, Staphylococcus epidermidis, Escherichia coli, etc. Media is supplied in its liquid form, in a sponge, suitable for direct extensions on slides. Dimensions of tube: 165x13 mm. PS shaft: 150x2.5 mm. Tip D=5 mm. Expiry date: 30 months after Sterilisation date.

22.300280
100 pc
30 month
wood stem / cotton head
150 x 2,5 mm
Cary Blair
Request a price Sale product
box

Swabs are Sterilised by radiation. Swab: CE MDD Class IIa. Tube: CE IVD. Cary Blair is another modification of Stuart media. The glycerophosphate has been substituted by inorganic phosphate since glycerophosphate is a metabolite for some bacteria, so they could grow and disgrise the pathogens amount. The methylene blue has also been removed and the pH increased to 8.4. This is a media originally developed for faecal samples but is also used successfully for anaerobic transport, such as: Neisseria gonorrhoeae, Vibrio cholerae, Vibrio parahaemolyticus, Haemophilus influenzae, Neisseria meningiditis, Bordetella pertusis, Streptococcus pneumoniae, Shigella flexneri, Pasteurella pestis, Campylobacter Spp., etc. Dimensions of tube: 165x13 mm. Wood shaft: 150x2.5 mm. Tip D=5 mm. Expiry date: 30 months after Sterilisation date.

Swabs are Sterilised by radiation. Swab: CE MDD Class IIa. Tube: CE IVD. Cary Blair is another modification of Stuart media. The glycerophosphate has been substituted by inorganic phosphate since glycerophosphate is a metabolite for some bacteria, so they could grow and disgrise the pathogens amount. The methylene blue has also been removed and the pH increased to 8.4. This is a media originally developed for faecal samples but is also used successfully for anaerobic transport, such as: Neisseria gonorrhoeae, Vibrio cholerae, Vibrio parahaemolyticus, Haemophilus influenzae, Neisseria meningiditis, Bordetella pertusis, Streptococcus pneumoniae, Shigella flexneri, Pasteurella pestis, Campylobacter Spp., etc. Dimensions of tube: 165x13 mm. Wood shaft: 150x2.5 mm. Tip D=5 mm. Expiry date: 30 months after Sterilisation date.

22.3002802
100 pc
30 month
polystyrene stem / viscose head
150 x 2,5 mm
Cary Blair
Request a price Sale product
box

Swabs are Sterilised by radiation. Swab: CE MDD Class IIa. Tube: CE IVD. Cary Blair is another modification of Stuart media. The glycerophosphate has been substituted by inorganic phosphate since glycerophosphate is a metabolite for some bacteria, so they could grow and disgrise the pathogens amount. The methylene blue has also been removed and the pH increased to 8.4. This is a media originally developed for faecal samples but is also used successfully for anaerobic transport, such as: Neisseria gonorrhoeae, Vibrio cholerae, Vibrio parahaemolyticus, Haemophilus influenzae, Neisseria meningiditis, Bordetella pertusis, Streptococcus pneumoniae, Shigella flexneri, Pasteurella pestis, Campylobacter Spp., etc. Dimensions of tube: 165x13 mm. PS shaft: 150x2.5 mm. Tip D=5 mm. Expiry date: 30 months after Sterilisation date.

Swabs are Sterilised by radiation. Swab: CE MDD Class IIa. Tube: CE IVD. Cary Blair is another modification of Stuart media. The glycerophosphate has been substituted by inorganic phosphate since glycerophosphate is a metabolite for some bacteria, so they could grow and disgrise the pathogens amount. The methylene blue has also been removed and the pH increased to 8.4. This is a media originally developed for faecal samples but is also used successfully for anaerobic transport, such as: Neisseria gonorrhoeae, Vibrio cholerae, Vibrio parahaemolyticus, Haemophilus influenzae, Neisseria meningiditis, Bordetella pertusis, Streptococcus pneumoniae, Shigella flexneri, Pasteurella pestis, Campylobacter Spp., etc. Dimensions of tube: 165x13 mm. PS shaft: 150x2.5 mm. Tip D=5 mm. Expiry date: 30 months after Sterilisation date.

22.300299
100 pc
12 month
polystyrene stem / polyester head
150 x 0,8 mm
for Chlamydia
Request a price Sale product
box

Swabs are Sterilised by radiation. Swab: CE MDD Class IIa. Tube: CE IVD. Liquid media, suitable for Chlamydia. For cervical samples it is recommended to firstly use a dry swab to clear the cervical channel. Media is supplied in its liquid form, in a sponge, suitable for direct extensions on slides. Sterilised by radiaton. Dimensions of tube: 165x13 mm. PS shaft: 150x2.5 mm. Tip D=5 mm. Expiry date: 12 months from Sterilisation.

Swabs are Sterilised by radiation. Swab: CE MDD Class IIa. Tube: CE IVD. Liquid media, suitable for Chlamydia. For cervical samples it is recommended to firstly use a dry swab to clear the cervical channel. Media is supplied in its liquid form, in a sponge, suitable for direct extensions on slides. Sterilised by radiaton. Dimensions of tube: 165x13 mm. PS shaft: 150x2.5 mm. Tip D=5 mm. Expiry date: 12 months from Sterilisation.

22.300291
100 pc
30 month
aluminium stem / cotton head
150 x 0,9 mm
Stuart
Request a price Sale product
box

Swabs are Sterilised by radiation. Swab: CE MDD Class IIa. Tube: CE IVD. The modified Stuart media allows the conservation and transportation of a large number of pathological microorganisms, such as: Neisseria gonorrhoeae, Haemophilus influenzae, Neisseria meningiditis, Bordetella pertusis, Corynebacterium diphteriae, Trichomonas vaginalis, Staphylococcus aureus, Streptococcus sp., Salmonella sp., Shigella sp., etc. The most unstable organisms will remain viable for up to 24 hours and other for several days. The media is reduced due to the presence of thioglycolate, which difficults the enzymatic reactions of the bacteria. The multiplication of the bacteria is prevented due to the lack of nitrogen in the media. Dimensions of tube: 165x13 mm. Al shaft: 150x0.9 mm. Tip D=5 mm. Expiry date: 30 months from Sterilisation date.

Swabs are Sterilised by radiation. Swab: CE MDD Class IIa. Tube: CE IVD. The modified Stuart media allows the conservation and transportation of a large number of pathological microorganisms, such as: Neisseria gonorrhoeae, Haemophilus influenzae, Neisseria meningiditis, Bordetella pertusis, Corynebacterium diphteriae, Trichomonas vaginalis, Staphylococcus aureus, Streptococcus sp., Salmonella sp., Shigella sp., etc. The most unstable organisms will remain viable for up to 24 hours and other for several days. The media is reduced due to the presence of thioglycolate, which difficults the enzymatic reactions of the bacteria. The multiplication of the bacteria is prevented due to the lack of nitrogen in the media. Dimensions of tube: 165x13 mm. Al shaft: 150x0.9 mm. Tip D=5 mm. Expiry date: 30 months from Sterilisation date.

22.300290
100 pc
30 month
wood stem / cotton head
150 x 2,2 mm
Stuart
Request a price Sale product
box

Swabs are Sterilised by radiation. Swab: CE MDD Class IIa. Tube: CE IVD. The modified Stuart media allows the conservation and transportation of a large number of pathological microorganisms, such as: Neisseria gonorrhoeae, Haemophilus influenzae, Neisseria meningiditis, Bordetella pertusis, Corynebacterium diphteriae, Trichomonas vaginalis, Staphylococcus aureus, Streptococcus sp., Salmonella sp., Shigella sp., etc. The most unstable organisms will remain viable for up to 24 hours and other for several days. The media is reduced due to the presence of thioglycolate, which difficults the enzymatic reactions of the bacteria. The multiplication of the bacteria is prevented due to the lack of nitrogen in the media. Dimensions of tube: 165x13 mm. Wood shaft: 150x2.5 mm. Tip D=5 mm. Expiry date: 30 months from Sterilisation date.

Swabs are Sterilised by radiation. Swab: CE MDD Class IIa. Tube: CE IVD. The modified Stuart media allows the conservation and transportation of a large number of pathological microorganisms, such as: Neisseria gonorrhoeae, Haemophilus influenzae, Neisseria meningiditis, Bordetella pertusis, Corynebacterium diphteriae, Trichomonas vaginalis, Staphylococcus aureus, Streptococcus sp., Salmonella sp., Shigella sp., etc. The most unstable organisms will remain viable for up to 24 hours and other for several days. The media is reduced due to the presence of thioglycolate, which difficults the enzymatic reactions of the bacteria. The multiplication of the bacteria is prevented due to the lack of nitrogen in the media. Dimensions of tube: 165x13 mm. Wood shaft: 150x2.5 mm. Tip D=5 mm. Expiry date: 30 months from Sterilisation date.

22.300295
100 pc
30 month
polystyrene stem / viscose head
150 x 2,5 mm
Stuart
Request a price Sale product
box

Swabs are Sterilised by radiation. Swab: CE MDD Class IIa. Tube: CE IVD. The modified Stuart media allows the conservation and transportation of a large number of pathological microorganisms, such as: Neisseria gonorrhoeae, Haemophilus influenzae, Neisseria meningiditis, Bordetella pertusis, Corynebacterium diphteriae, Trichomonas vaginalis, Staphylococcus aureus, Streptococcus sp., Salmonella sp., Shigella sp., etc. The most unstable organisms will remain viable for up to 24 hours and other for several days. The media is reduced due to the presence of thioglycolate, which difficults the enzymatic reactions of the bacteria. The multiplication of the bacteria is prevented due to the lack of nitrogen in the media. Dimensions of tube: 165x13 mm. PS shaft: 150x2.5 mm. Tip D=5 mm. Expiry date: 30 months from Sterilisation date.

Swabs are Sterilised by radiation. Swab: CE MDD Class IIa. Tube: CE IVD. The modified Stuart media allows the conservation and transportation of a large number of pathological microorganisms, such as: Neisseria gonorrhoeae, Haemophilus influenzae, Neisseria meningiditis, Bordetella pertusis, Corynebacterium diphteriae, Trichomonas vaginalis, Staphylococcus aureus, Streptococcus sp., Salmonella sp., Shigella sp., etc. The most unstable organisms will remain viable for up to 24 hours and other for several days. The media is reduced due to the presence of thioglycolate, which difficults the enzymatic reactions of the bacteria. The multiplication of the bacteria is prevented due to the lack of nitrogen in the media. Dimensions of tube: 165x13 mm. PS shaft: 150x2.5 mm. Tip D=5 mm. Expiry date: 30 months from Sterilisation date.

related products

Sterile sampling swab in two types of packaging
Request a price Quotation
Sterile sampling swabs, 2 units
Sterile sampling swabs, 2 units

Peel-pack, suitable for cleaning the area and taking samples.

More informations
Request a price Quotation
Purity sampler (TiMi) set, sterile
Request a price Quotation
Cotton swab for sampling
Cotton swab for sampling

Stem: wood, PP, PS, or aluminum. Head: cotton or viscose. Not sterile

More informations
Request a price Quotation
Cotton swab for hospital use, with a 11 mm diameter cotton head
Cotton swab for hospital use, with a 11 mm diameter cotton head

For cleaning the sampling area and treating it with disinfectant liquid

More informations
Request a price Quotation
Sterile sampling swab in labeled storage tube
Request a price Quotation
Cytology brush
Request a price Quotation
IKA Rotavisc viscometers
Velp automatic extractor